INSTALLATION INSTRUCTIONS
WARNING
Fire hazard: Do not use a fl ame to check for gas leaks.
Recommended gas and electric supply location
When using test pressures greater than 1/2 psig to pressure test the gas supply system of the residence,
disconnect the range and individual shut-off valve from the gas supply piping. When using test pressures
of 1/2 psig or less to test the gas supply system, simply isolate the range from the gas supply system by
closing the individual shut-off valve.
Note: Recommended gas hook-up locations behind the range. Gas and shut-off valve should not protrude
more than 2” from the wall to allow the range to rest against the wall.
Check local codes before making connections.
1. Electrical connection area
2. Gas hook-up area
A. 20 3/8”
B. (minimum distance to
walls above the cooktop
on each side): 2”
C. 2”
D. 2 1/2”