INSTALLATION INSTRUCTIONS
12
To reduce the risk of the appliance tipping, the anti-
tip bracket must be installed before operation.
Note: The installation of the anti-tip bracket must
meet all local codes for securing the appliance.
The anti-tip bracket must be secured to either the
rear wall or the fl oor and must be positioned in such
a way that it will overhang the anti-tip arm on the
rear of the appliance.
Rear wall installation
Use the two screws provided to secure the bracket
to the rear wall. The screws must enter a wood sill
plate. If the wall contains any metal studs or similar
materials, or if the back of the appliance cannot
reach the rear wall, the fl oor installation should be
used.
Floor installation
Wood fl oor: Use the two screws provided to secure
the bracket to the fl oor.
Concrete fl oor:
1. Mark the location where the screws need to be
installed.
2. Use a power drill and a concrete bit to drill a
5/32” pilot hole 2” deep into the concrete at the
center of each of the marked locations.
3. Use the two screws provided to secure the
bracket to the fl oor.
Double check the installation
After installing the bracket, slide the appliance into
its fi nal location. Look underneath the appliance
and ensure that the anti-tip arm attached to the side
panel of the appliance is engaging the bracket.
ANTI-TIP BRACKET INSTALLATION
1. Anti-tip arm on the back of the appliance
2. Anti-tip bracket
3. Screw must enter wood or concrete
4. Wall sill plate
5. Screw must enter wood
1
2
3
4
5
ELECTRICAL CONNECTIONS
Electrical requirements:
120 volt, 60 hertz, properly grounded dedicated
circuit protected by a 15 amp or 20 amp circuit
breaker or time delay fuse.
NOTE: Use of automatic, wireless, or wired external
switches that shut off power to the appliance are not
recommended for this product.
WARNING SHOCK HAZARD: This appliance must
be properly grounded. Failure to do so can result in
electric shock.
The power cord of this appliance is equipped with
a three prong (grounding) plug which mates with
a standard three-prong grounding wall receptacle
to minimize the possibility of electric shock hazard
from this appliance.
The customer should have the wall receptacle and
circuit checked by a qualifi ed electrician to make
sure the receptacle is properly grounded.
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR
REMOVE THE THIRD (GROUND) PRONG FROM
THE POWER CORD.
DO NOT USE AN ADAPTER.
DO NOT USE AN EXTENSION CORD.
A word about GFCIs - GFCIs are not required or
recommended for gas range receptacles.
Ground Fault Circuit Interrupters (GFCIs) are
devices that sense leakage of current in a circuit and
automatically switch off power when a threshold
leakage level is detected. These devices must be
manually reset by the consumer. The National
Electrical Code requires the use of GFCIs in kitchen
receptacles installed to serve countertop surfaces.
Performance of the range will not be affected if
operated on a GFCI-protected circuit but occasional
nuisance tripping of the GFCI breaker is possible.