WATER DRAINAGE
During dehumidifying modes, remove the drain plug from the back of the
unit, install the drain connector (5/8” universal female connecter) with
3/4” hose (not included). For the models without a drain connector, just
attach the drain hose to the hole. Place the open end of the hose
directly over the drain area in your basement floor. Please refer to
Fig.22a, b & 23.
When the water level of the bottom tray reaches a predetermined level,
the unit beeps 8 times, the digital display area shows P1. At this time
the air conditioning/dehumidification process will immediately stop.
However, the fan motor will continue to operate (this is normal).
Carefully move the unit to a drain location, remove the bottom drain plug
and let the water drain away (Fig.24). Restart the machine until the P1
symbol disappears. If the error repeats, call for service.
NOTE: When operating or draining water always protect carpeting or
floors from possible water spillage.