Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation resulting from to ignoring these instructions may cause harm or damage.
ENERGY SAVING
TIPS
Use the unit in the recommended room size.
Locate the unit where furniture cannot obstruct the air flow.
Keep blinds/curtains closed during the sunniest part of the day.
Keep the filters clean.
Keep doors and windows closed to keep cool air in and warm air out
(cooling mode).
OPERATING
CONDITION
The air conditioner must be operated within the temperature range
indicated below:
TOOLS FOR WINDOW
KIT INSTALLATION
1. Screwdriver (medium size, Phillips)
2. Tape measure or ruler
3. Knife or scissors
4. Saw (In the event that the window kit needs to be cut down in size
because the window is too narrow for direct installation).
See www.danby.com for general instruction guide.
Identifying Parts
WARNING
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Avoid fire hazard or electric shock. Do not use an extension cord
or an adaptor plug. Do not remove any prong from the power
cord.
ELECTRICAL
INFORMATION
WARNING
Be sure the electrical supply is adequate for the model you have
chosen. This information can be found on the serial plate, which
is located on the side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize
shock and fire hazards, proper grounding is important. The
power cord is equipped with a three-prong grounding plug for
protection against shock hazards.
Your air conditioner must be used in a properly grounded wall
receptacle. If the wall receptacle you intend to use is not
adequately grounded or protected by a time delay fuse or circuit
breaker, have a qualified electrician install the proper receptacle.
Ensure the receptacle remains accessible after the unit is
installed.
4
MODE
COOL
DRY
*HEAT (heat pump type)
*HEAT (electrical or heat pump)
ROOM TEMPERATURE
17°C (62°F) ~ 35°C (95°F)
13°C (55°F) ~ 35°C (95°F)
5°C (41°F) ~ 30°C (86°F)
<30°C / 86°F
(*) Optional feature, some models may not have this feature.
Note: Performance may be reduced outside of these operating
temperatures.