Danby DDW1804EW Owner's Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
4
INSTALLATION INSTRUCTIONS
Connecting the hot water line
Run the hot water line through the channel on the
bottom left side of the appliance. Make sure the hot
water line is not twisted and then connect it to the
appliance using an elbow joint. Use Tefl on tape or
sealing compound on the connection to avoid leaks.
Do not over tighten the 90° elbow. This can damage
the water inlet and cause a leak.
Connecting the drain line
The drain hose will connect to the drain pump on
the bottom of the appliance. Run the drain line in
the same channel on the bottom of the appliance
as the hot water line. Ensure there is nothing inside
the drain hose and that it does not tear during the
installation process.
There are a number of different ways to connect
the drain hose depending on the confi guration of
the sink. Review the different ways of connecting
the drain system and choose a method that best
suits the application. Local codes may require the
installation of an air gap kit. Check with a qualifi ed
plumber if there is any doubt.
1. Air gap
2. Air gap with garbage disposal
3. No air gap
4. No air gap with garbage disposal
Use a rubber connector to connect drain hoses and
hose clamps on all connection points.
Secure the drain hose to the sink wall using cable
ties or other fastening materials. If not fastened, the
drain hose may bend causing drainage problems.
The drain hose internal diameter is 0.8 inches (21
mm).
The top of the drain hose must be less than 39
inches (100 cm) from the fl oor.
If the drain hose is not looped up the water may
siphon out during a wash cycle.
Any bends in the drain hose must be supported so
that the hose will not kink or bend.
1
2
3
4
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 43 44

Comments to this Manuals

No comments