Electrical Specifications
1.
All wiring must comply with local and national
electrical codes and be installed by a qualified
electrician. If you have any questions regarding
the following instructions, contact a qualified
electrician.
2. Check available power supply and resolve any
wiring problems BEFORE installation and
operation of this unit.
3. This unit draws 9.0 amps (nameplate rated)
under
Cooling Mode and 12.0 amps (nameplate
rated) under Heating Mode and may be used in
any properly wired, general purpose 15 amp
household grounded receptacle.
4.
For your safety and protection, this unit is
grounded through the power cord plug when
plugged into a matching wall outlet. If you are
not sure whether the wall outlets in your home
are properly grounded, please consult a qualified
electrician. DO NOT USE PLUG ADAPTERS
OR EXTENSION CORDS WITH THIS UNIT.
If it is necessary to use an extension cord with
this unit, use an approved “air conditioner
extension cord only. (available at most local
hardware stores)
5. The manufacturers nameplate is located on the
rear panel of the unit and contains electrical and
other technical data specific to this unit.
6. To avoid the possibility of personal injury, always
disconnect the power supply to the unit, before
installing and/or servicing.
Table 1
Suggested Individual Branch Circuit
Nameplate Amps AWG Wire Size*
7.4 to 12.0 14
AWG- American Wire Gage
* Based on copper wire at 60°C temperature rating.
Table 2
Receptacle and Fuse Types
Rated V
olts 125
Amps 15
Wall Outlet
Fuse Size 15
Time Delay Fuse Plug Type
(or circuit breaker)
Unit Specifications: Model SPAC8499
Cooling Capacity 8400 Btu/h
Heating Capacity (High/Low) 1380W/830W
Dehumidifying Capacity 57 Pints (27 L / 24 Hrs)
Noise Level Less than 54 dB(A)
Power Source 115 V / 60 Hz
Refrigerant R22
Internal W
ater Tank Capacity 5.5 L (11.6 Pints)
External Water Tank Capacity 8.5 L (18 Pints)
Unit Weight 38 kg (83.7 lb.)
Unit Dimensions (inches) W x D x H 15
1
/4" x 18" x 32
5
/8"
Unit Dimensions (cm) W x D x H
38.7 x 45.6 x 82.9
Fan Speeds 3
Control Panel (Illuminated) Soft Touch Controls
Remote Control
Y
es
Time of Day Clock Yes
Auto - Timer Yes
Power Consumption:
Cooling
1050 W
atts (9.0
Amps)
Heating 1380 Watts (High) 12 Amps
830 W
atts (Low) 7.2
Amps
Dehumidifying
1050 W (9.0 Amps)
Fan
90 W (0.8 Amps)
NOTE: Specifications are subject to change without notice, for further improvements.