Remote Control Operating
Instructions (cont’d)
6. Swing Setting: Press the remote “Swing”
button to activate the automatic air swing
(oscillation) feature. The symbol " " will
momentarily appear in the LCD window
confirming the "swing" feature is activated and/or
deactivated.
7. L (Lock) Button: Press the remote “L” button to
guard against accidental program change. When
the “L” button is depressed, the lock symbol ( )
will be displayed in the remote LCD window.
Press the
“L” button again to unlock the
registered program (key symbol will disappear).
8. R (Re-set) Button: Press the remote “R” button
to cancel all remote control programs. This will
erase all information contained within the remote
LCD window (including time of day clock).
9. ˚C/˚F: Used to select/display temperature
settings in either “Celsius” or “Fahrenheit” on
the hand held remote unit only. Press the remote
(˚C/˚F) button (using pencil tip) to select either the
Celsius or Fahrenheit scale.
NOTE: To change the temperature display on the
main unit, press the (Temp/Clock) “ “ keypad
& “Clock” keypad simultaneously to alternate
between the˚C & ˚F scale.
NOTE: When turning off the main unit with the
remote control, there may be a delayed (off)
reaction (5-15 seconds) before the unit actually
stops. This is normal.
How the External Water Tank
Feature Works
This unit is featured with a factory installed "Quick
Connect" and "External Water Tank" feature. When
the external tank is connected to the main unit, it will
"increase" the total running time of the main unit, (air
conditioner and dehumidifying mode) up-to 12 hours,
inclusive of both tanks. (Depending on relative
humidity conditions)
During air conditioner and dehumidifying
modes, condensed water accumulates in a pre-
cooler drip tray located underneath the evaporator
(cooling) coil. When the water reaches a
predetermined level, the water flow is channeled first
into the secondary external water tank. When the
water level inside the secondary tank reaches a
predetermined level, the water flow will reverse
(backwards) and be re-directed into the primary
internal tank. When the water level inside the
primary tank reaches a predetermined level, the
automatic float switch mechanism (safety shut-off) is
activated, causing the unit to stop automatically. The
fan motor will continue to operate after the water
condensing cycle has terminated. (this is normal)
NOTE: The float switch mechanism is activated
by the water level inside the (primary) internal
tank only.
If the external water tank is not connected to the
main unit, water flow is automatically directed inside
the internal water tank.
SPECIAL NOTE:
(Air Conditioner & Dehumidifier Modes Only)
This unit can operate without the secondary
external water tank being installed, providing the
primary "internal" water tank is correctly installed.
• This unit cannot operate if the secondary external
water tank is installed, but the primary internal water
tank is not.
NOTE:
The quick connect fittings supplied with both the
main unit and external water tank are "self-sealing"
connections.
• This means as soon as the quick connects are
"disconnected", water flow between the main unit
and external water tank stops immediately
.