Trouble.Shooting Guide
Sometimes you may come across minor problems
that In mostcases do not require a service call and
can be easily ellmlnated_The problem may have
resulted from improper handling and/or installation of
the appliance. Please refer to the below trouble-
shooting guide to assist you In identifyingthe
possible cause and-solulion to your problem,. Should
the problem still persist after completing these
checkpoints. Contact the closest authorized service
agent in your area for assistance..
The Appliance Fails to
Operate After Connecting to
Electrical Power Supply
Check the power cord is properly connecled.
Check the power supply in the electrical outieL
(blownfuse I circuitbreaker)
Make sure the appliance is switched on_
(thermostat knob In operating position)
Continuous Operation of the
Cooling System
- "[he door Is frequently opened or left open for
too long.
'The door is not properly closed (the door may sag,
the gasket may be polluted or damaged).,
Perhaps you may have overloaded the appliance
with fresh foods..
the reason may be inadequate vent!lotion of the
compressor (assure adequate air circulation).
Ice Formation on the Inner
Rear Wall
As long as the defrost water runs to the channel and
throughthe outlet to the drain pan on the
compressor,automatic defrosting of the appliance
is assured.
In case theice formation on the inner back wall ts
increased (3..5mm), ice should be manually
defrosted.
Sat the thermostat knob _o STOP (0) position and
leave the door open..Never use electric devices for
defrostingand do not scrape the ice or frost layer
wilh sharp objects.
increased ice formallon may be one of the following:
1he door does not se'alwell (clean the gasket if it is
contaminated, or replace it If it is damaged);
-the door is frequenliy opened or left too long;
-the food slored in the refrigerator was warm;
-the food or dish ts touching the inner back wall.
Water is Leaking From the
Refrigerator
If the discharge water outletis clogged, or the
defrost water drips overthe channel, water will leak
from the reldgeratoro
Clean the dogged ou!iel, for example with a
plast]c straw,
Manually defrost the increased ice layer. See
"Ice Formation on the Inner rear Wall"
Noise
Cooling in a refrigerator-freezingappliance is made
possible by cooling the system using a compressor,
which will produce certain noise levels..How noisy the
appliance is depends on where tt is placed, how It is
used and how old the appliance is.
During lhe operation of the compressor the
noise of the liquid is heard and when the compressor
is not operating, the refrigerant flow Is heard.This is
a normal condition and it has no influence
whatsoever on the lifetime of the appliance.
- After staffing the appliance, the operation of
the compressor and the refrigerantflow may be
louder, which does not mean that something is wrong
with the appliance and it has no influence on the
lifetime of the appliance. Gradually the is noise
reduced.
Some_mes ur=usua! and louder noise is heard,
which is rather unusual for the appliance, This noise
is often a consequence of inadequate installation.
-The appliance must be level and Installed on a firm
solid baselllooro
-It should not touch thewail or Idtchen units standing
next to It.
-Check the accessories on the interior of the
appliance, 1hey should be placed correctly in their
positions; also check, bottles, lins, and other vessels
are not touching each other causing rattling
and/or vibrations.
After defrosting is complete, turn the knob to desired
position and close the refrigerator daorThe cause of
10