PROBLEM POSSIBLE CAUSE
The unit does not operate Not plugged in
The circuit breaker tripped or blown fuse
Turns on and off
frequently
The room temperature is hotter than normal
The door is open too often
The door is not closed completely
The temperature control is not set correctly
The door gasket does not seal properly
The unit does not have proper clearance
Vibrations Check that the keg cooler is level
The keg cooler seems to
make too much noise
The rattling noise may come from the ow of refrigerant, which is
normal
Gurgling, caused by liquid refrigerant cycling is normal
Contraction and expansion of the inside walls may cause popping
and crackling noises
The keg cooler is not level
The door will not close
properly
The keg cooler is not level
The door was reversed and not properly reinstalled
The gasket is dirty
The shelves or stand are out of position
The keg is not properly centered in the unit
The casters are not attached
Excessive beer foam Ensure the beer line hose from the tower and the CO
2
air line hose
from the CO
2
regulator are attached to the correct connections on
the coupler; beer line to the top of the coupler, CO
2
air line to the
side of the coupler
Check that there are no leaks in any connections
Ensure that the reed valve in the CO
2
connection at the coupler
has a hole in it
• The CO
2
pressure may be set too high; try turning the pressure
down
Ensure that the valve spool plastic rod is inserted into the coupler
Weak beer ow Ensure the beer line hose from the tower and the CO
2
air line hose
from the CO
2
regulator are attached to the correct connections on
the coupler; beer line to the top of the coupler, CO
2
air line to the
side of the coupler
Check that there are no leaks in any connections
Ensure that the reed valve in the CO
2
connection at the coupler
has a hole in it
• The CO
2
pressure may be set too low; try turning the pressure up
Ensure there are no bends or kinks in any of the hoses that could
impede ow
15