PROBLEM POSSIBLE CAUSE SOLUTION
• Unit does not work
Air from unit does not feel
cold enough
Air conditioner cooling but
room is too warm- ice
forming on cooling coil
behind decorative front.
Air conditioner cooling but
room is too warm- NO ice
forming on cooling coil
behind decorative front.
Air conditioner turns on and
off rapidly.
• Noise when unit is cooling.
• Water dripping INSIDE when
unit is cooling.
• Water dripping OUTSIDE
when unit is cooling.
• Remote Sensing
deactivating prematurely.
• Room too cold.
• Power is out
• The plug is not plugged in properly
• Plug current device tripped.
• Control is Off
• Room temp. below 17°C (62°F)
• Temp. sensing element touching
cold coil (behind air filter)
• Temp. set too high
• Compressor shut off by changing
modes.
• Outdoor temp. below 17°C(62°F)
Air filter may be dirty
• Thermostat too cold for night-time
cooling.
• Dirty air filter- air restricted
• Temp. is set too high
Air directional louvers positioned
improperly
• Front of unit blocked(i.e. by
drapes), restricting air distribution.
• Doors, windows, registers etc.
open, cold air escaping.
• Unit recently turned on in hot
room.
• Dirty air filter- air restricted
• Outside temp. extremely hot.
Air movement sound
• Window vibration
• Improper installation
• Unit removing large quantity of
moisture from humid room.
Remote control not located within
range.
• Remote control signal obstructed.
• Set temperature too low.
Wait for power to return
• Plug in properly
• Press the reset button after
resolving problem
• Turn control ON and set to
desired setting.
• Will not cool until room temp.
rises above 17°C(62°F)
• Straighten tube away from coil.
• Reset to a lower temp.
• Wait approx. 3 minutes and listen
for compressor to restart when in
cool mode.
• To defrost coil, set to FAN ONLY
Clean filter as per instructions
• Set temp. to a higher setting
• Clean air filter
• Set to lower temp.
• Position louvers for better air
distribution.
• Clear blockage in front of unit
• Close doors, windows, registers.
Allow additional time to remove
“stored heat” from room.
• Clean air filter.
• Set fan speed to higher setting to
bring air past cooling coils more
frequently.
• This is normal. If too loud, set to
slower fan setting.
• Poor installation- refer to
installation instructions or check
with installer.
• Tilt air conditioner slightly to the
outside to allow water drainage.
• This is normal during excessively
humid days.
• Place remote control within 20 feet
& 180° radius of front of unit.
• Remove obstruction.
• Increase set temperature.
Occasionally, a problem may occur that is minor, and a service call may not be necessary. Use this troubleshooting
guide for a possible solution. If the unit continues to operate improperly, call an authorized service depot or Danby’s Toll
Free Number for assistance. 1-800-263-2629