INSTALLATION INSTRUCTIONS
Install Support Bracket
1) Hold each support bracket flush against outside of sill, and tighten to bottom of cabinet as shown in Fig. J1. Mark
brackets at top level of sill, and remove.
2) Assemble sill anchor bracket to outside support legs at the market positon, as seen in Fig. J2. Hand tighten, but allow
5
3) Install support brackets (with sill anchor brackets attached) to correct hole in bottom of cabinet
as shown in Fig. K.
4) Tighten all 6 bolts securely.
Mark
Fig. J1
Left
Locknut
Sill Anchor
Bracket
Flat Head
Bolt
2 Each Required For
Each Support Bracket
Right
1/2in.(12.7mm) Long
Left Screws And
Locknuts
Fig. J2
Fig. K
Extend Window Filler Panels
6
Install Window Lock and Sash Seal
1) Trim sash seal to fit window width. Insert into space between upper and lower sashes (Fig. M).
2) Attach right angle safety lock as shown in Fig. M.
7
Install Chassis into Cabinet and Install Front to Unit
1) Lift chassis and carefully slide into cabinet, leaving 6 inches protruding.
2) DO NOT push on controls or coils.
3) Be sure the chassis is firmly seated towards rear of cabinet.
4) Installation of front is the reverse of removal, outlined in section 1(“Remove Chassis”).
8
Safety Lock
1/2” screw
Window
Sash Seal
Fig.M
14
for any changes later. NOTE: Check that air conditioner is tilted downwards to the outside, about 3° to 4°, as shown in Fig. I.
Window Sill
Window Sash
About 1¼ " to 1⅝"
Sill Angle Bracket
Side Louvers
Fig. I
h
locking screw &
flat washer.
13/16in.(20mm) Screw & Frame Lock (2)
Fig.L
1) Extend panels to fill window opening completely. Secure the shutter clamp on each side of the (upper) shutter and
secure to window sill using one 7/16in.(12mm) locking screw & flat washer on each side. (Fig.L)
2) Attach frame lock to window sill using one 13/16in. (20mm) screw on each side as shown in Fig. L.
3) Close window behind “L” bracket as seen in Fig. L.
7/16in.(12mm)
After proper installation, condensed water should not drain from the overflow drain hole during normal use. If you notice
water leaking out , check the angle of tilt, and make any necessary adjustments. However, on a very humid day, water
leakage can occur – this is normal. Measure the tilt angle from the cabinet’s edge. The distance H should be approximately
1 1/4” to 1 5/8”.