Danby DAC15009EE Operations Instructions Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
PROBLEM POSSIBLE CAUSE SOLUTION
• Unit does not work
Air from unit does not feel cold
enough
Air conditioner cooling but
room is too warm- ice forming
on cooling coil behind
decorative front.
Air conditioner cooling but
room is too warm- NO ice form-
ing on cooling coil behind deco-
rative front.
Air conditioner turns on and off
rapidly.
• Noise when unit is cooling.
• Water dripping INSIDE when
unit is cooling.
• Water dripping OUTSIDE
when unit is cooling.
• Remote Sensing
deactivating prematurely.
• Room too cold.
• Power is out
• The plug is not plugged in properly
• Plug current device tripped.
• Control is Off
• Room temp. below 17°C (62°F)
• Temp. sensing element touching cold
coil (behind air filter)
• Temp. set too high
• Compressor shut off by changing
modes
• Outdoor temp. below 17°C(62°F)
Air filter may be dirty
• Thermostat too cold for night-time
cooling.
• Dirty air filter- air restricted
• Temp. is set too high
Air directional louvers positioned
improperly
• Front of unit blocked(i.e. by drapes),
restricting air distribution.
• Doors, windows, registers etc. open,
cold air escaping.
• Unit recently turned on in hot room.
• Dirty air filter- air restricted
• Outside temp. extremely hot.
Air movement sound
• Window vibration
• Improper installation
• Unit removing large quantity of
moisture from humid room.
• Remote control not located within
range.
• Remote control signal obstructed.
• Set temperature too low.
• Wait for power to return
• Plug in properly
• Press the reset button after
resolving problem
• Turn control ON and set to
desired setting.
• Will not cool until room temp. rises
above 17°C(62°F)
• Straighten tube away from coil.
• Reset to a lower temp.
• Wait approx. 3 minutes and listen for
compressor to restart when in cool
mode.
• To defrost coil, set to FAN ONLY
Clean filter as per instructions
• Set temp. to a higher setting
• Clean air filter
• Set to lower temp.
• Position louvers for better air
distribution.
• Clear blockage in front of unit
• Close doors, windows, registers.
Allow additional time to remove
“stored heat” from room.
• Clean air filter.
• Set fan speed to higher setting to
bring air past cooling coils more
frequently.
• This is normal. If too loud, set to
slower fan setting.
• Poor installation- refer to installation
instructions or check with installer.
• Tilt air conditioner slightly to the out-
side to allow water drainage.
• This is normal during excessively
humid days.
• Place remote control within 20 feet &
180° radius of front of unit.
• Remove obstruction.
• Increase set temperature.
Occasionally, a problem may occur that is minor, and a service call may not be necessary. Use this
troubleshooting guide for a possible solution. If the unit continues to operate improperly, call an authorized
service depot or Danby’s Toll Free Number for assistance.
TROUBLESHOOTING
12
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 25 26

Comments to this Manuals

No comments