Danby DAC120EUB2GDB Use and Care Manual Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
Occasionally a problem may arise that is minor in nature, and a service call may not be neccessary. Use this troubleshoot-
ing guide for a possible solution. If the unit continues to operate improperly, call an authorized service depot or
Danby’s Toll Free Number 1-800-263-2629 for assistance.
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
Air conditioner will
not operate
No power to the unit Check connection of power cord to power
source.
Check fuse or circuit breaker.
Set SELECTOR SWITCH to position other than
“OFF”. The power cord “RESET” button must
always be pushed in (engaged) for correct oper-
ation.
Inef cient or no
cooling
• Dirty air lter Clean/replace air lter
Unit size inappropriate for application Check with dealer to determine proper unit ca-
pacity for application
• Blocked air ow Remove obstruction from grill or outdoor louvres
Power interruption, settings changed
too quickly, or compressor overload
tripped
Turn the unit off and wait 5 minutes before at-
tempting to restart
Noisy unit Loose parts Tighten loose parts
Inadequate support Provide additional support to unit
Odors Formation of mold, mildew, or algae
on wet surfaces
Clean unit thoroughly
Place algaecide tablet in base pan
Water dripping
outside
Hot and humid weather Condensation run-off is normal under these
conditions.
Water dripping inside Unit is not properly angled to allow
water to drain outside
Unit must be installed on an angle for proper
condensation run-off. Check the unit and make
any adjustments.
It is an extremely humid day On an extremely humid day, this effect is expect-
ed. No action required.
Ice or frost build-up Low outside temperature When outdoor temperature is approximately
18.3°C (65°F) or below, frost may form when
unit is in cooling mode. Switch unit to FAN (only)
operation until frost melts.
• Unit air lter is dirty Remove and clean lter
NOTES:
1. If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a quali ed technician.
2. When the unit is installed using proper installation steps, the unit is properly tipped toward the outdoors to allow for
condensation run-off.
16
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 39 40

Comments to this Manuals

No comments