CONTROLS
Operating Instructions
6
6) POWER BUTTON
Press to turn the dehumidifier on and off.
7) Display
Shows the set % humidity level from 35% to 85% or auto start/stop time
(0~24) during setting, then shows the actual (± 5% accuracy) room %
humidity level in a range of 30% RH(Relative Humidity) to 90%RH
(Relative Humidity).
Error Codes and Protection Codes:
AS - Humidity sensor error--Unplug the unit and plug it back in. If error
repeats, call for service.
ES - Temperature sensor error-- Unplug the unit and plug it back in. If
error repeats, call for service.
P1 - Unit is defrosting-- Allow the unit time to automatically defrost. The
error will clear after the unit self defrosts.
P2 - Bucket is full or the bucket is not in right position--Empty the bucket
and replace in the right position.
E1 - unit malfunction -- Unplug the unit and plug it back in. If error repeats,
call for service.
INDICATOR
LIGHT FUNCTION
Power Light (Green):
the factory
default setting:
Humidity Setting: 60%
Fan Speed: High
IMPORTANT NOTE: Depending on the humidity conditions of the sur-
the “on/off” button is pressed (see dehumidifier operating instructions for
gram setting that was used when power is restored.
Water Full Indicator Light (Red):
This is
a safety feature. When the
water tank is emptied and/or correctly re-positioned, the dehumidifier will
resume operation automatically. NOTE: It may take several minutes before
operating conditions resume.
Memory Setting:
Each time the unit is disconnected/re-connected and/or in the event of a
power failure, the electronic circuit board automaticallydefaults to the last
program setting that was used. It may take several minutes before operat-
ing conditions resume.
NOTE: In the event of a power failure, all previous settings are automati-
cally erased/cancelled. If your program setting was different than above
(default setting) it will be necessary to re-program your settings. When the
unit is switched “off” manually (using the on/off keypad) the unit will always
default to the last program setting that was used.
When the water tank is full and/or incorrectly positioned inside the cabinet,
the (water full) red light turns on and remains on until such time the tank is
shut down of the compressor immediately and
fan motor operation
When the unit is first connected to an electrical outlet, the (green) power
light
turns on.
emptied and/or correctly re-positioned. This condition will result in the
shut down after 30 seconds.
to a state “on” condition. The dehumidifier will automatically default to
rounding environment, the dehumidifier may not start automatically when
ton is activated, the power light turns
details). In the event of a power failure, the unit will default to the last pro-
When the “on/off” but