Danby DAC7024DE Specifications Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
Frequently,a problem is minor and a service call may not be necessary, use thistroubleshootingguide for a
possible setulion If Ihe unit continues to operale improperly+call Danby's Toll Free Number 1-800-263-2629 for
assistance, or call one of our service depots listed in the enclosed "Authorized Service Depot"listingprovided
with thisunit
Possible Cause
No powerto unite
Difficulty
Air conditioner will
not operate.
Dirty air filter
Unit size inappropriate
for application..
Blocked air f_ow,.
Inefficient or no cooling+
Power inlerruplton, setlings
changed too quickly, or
compressor overload Iripped_
Suggested Solution
Check conneclion of power cord to
power source.,
Check fuse or circuit breaker.
Check the appropriate setting +sselected
Clean or replace air filter.
Check wlth dealer to determine proper unit
capacity for application
Remove obstruction from grill or
outdoor louvers
Tum the unit off and wait 5 minutes before
attempting to restart
Loose pa_s
Inadequate suppod_
Form_mn of mold, mildew, or
algae on wetsuffeceso
Water ddpping outside° Condensation run-off is normal
during hot and humtd weather.+
Water ddppIng Inside. Unit is not properly angled to
allow water to drain oulside
Ice or frost build-up_ Low outside temperature,
Unil air filler is dirty
Tighten toosa paris
Provide add+lional support to unit.
Clean unit thoroughly.
Place algaeoide tablet in base pan+
Add flexible tubing to redirect water flow,
see Fig25
Unit must be installed on an angle for proper
condensation run-off. Check the unit and
make any adjustments.
When outdoor temperature is approximately
65"F or betow, frost may form when unit is in
cooling mode. Switch unit to FAN (onty)
operation unlil frost molls+
Remove and clean filter.
NOTES:
1. If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a
qualified fechnlctano
2.. When unit is insta!ted using proper instailafion steps, unit is propefly tipped towards the
outdoors to a/few forcondensation run+o_.
13
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 29 30

Comments to this Manuals

No comments