INSTALLATION INSTRUCTIONS
7
To reduce the risk of the appliance tipping, the anti-
tip bracket must be installed before operation.
Note: The installation of the anti-tip bracket must
meet all local codes for securing the appliance.
The anti-tip bracket must be secured to either the
rear wall or the fl oor and must be positioned in such
a way that it will overhang the anti-tip arm on the
rear of the appliance.
Rear wall installation
Use the two screws provided to secure the bracket
to the rear wall. The screws must enter a wood sill
plate. If the wall contains any metal studs or similar
materials, or if the back of the appliance cannot
reach the rear wall, the fl oor installation should be
used.
Floor installation
Wood fl oor: Use the two screws provided to secure
the bracket to the fl oor.
Concrete fl oor:
1. Mark the location where the screws need to be
installed.
2. Use a power drill and a concrete bit to drill a
5/32” pilot hole 2” deep into the concrete at the
center of each of the marked locations.
3. Use the two screws provided to secure the
bracket to the fl oor.
Double check the installation
After installing the bracket, slide the appliance into
its fi nal location. Look underneath the appliance
and ensure that the anti-tip arm attached to the side
panel of the appliance is engaging the bracket.
ANTI-TIP BRACKET INSTALLATION
1. Anti-tip arm on the back of the appliance
2. Anti-tip bracket
3. Screw must enter wood or concrete
4. Wall sill plate
5. Screw must enter wood
1
2
3
4
5
ELECTRICAL REQUIREMENTS
ALL NEW BRANCH CIRCUIT INSTALLATIONS,
MOBILE HOMES, RECREATIONAL VEHICLES AND
INSTALLATIONS WHERE LOCAL CODES DO NOT
ALLOW GROUNDING THROUGH NEUTRAL,
REQUIRE A 4-CONDUCTOR CORD OR CONDUIT
Use only a 3-conductor or a 4-conductor UL-listed
range cord. These cords may be provided with ring
terminals on wire and a strain relief device.
A range cord rated at 40 amps with 125/250
minimum volt range is required. A 50 amp range
cord is not recommended but if used, it should
be marked for use with nominal 1 3/8” diameter
connection openings. Care should be taken to
center the cable and strain relief within the knockout
hole to keep the edge from damaging the cable.
Because range terminals are not accessible after
the range is in position, a fl exible service conduit or
cord must be used.
On some models, a fi lter capacitor may be
connected between the black and white leads on the
junction block.