TROUBLESHOOTING
The troubleshooting cheek list is common for all dishwasher models.
They use different parts to accomplish the same thing and diagnosis will
remain similar.
When a problem arises, and a possible cause is listed, follow the test,
remove or replace procedures as outline in this service manual. The
wiring diagram, shematic and timer cycle chat is a necessity when
making electrical checks. In most cases an ohmmeter will handle all the
tests necessary.
For checking any particular cycle of operation, it absolutely necessary
that the cycle be set up as outlined in the product owner’s guide.
SYMPTOM
CHECK THE
FOLLOWING
REMENDY
Dishwasher will not
operation when turn on
fuse (blow nor tripped)
Supply line receptacle, wiring
harness.
Timer (contacts open or burnt).
Motor (inoperative, check
resistances).
Door switch (open contacts)
Door latch not making contact
with door switch.
Replace fuse or reset breaker.
Repair or replace.
Replace timer.
Replace motor.
Replace door switch.
Replace or adjust to make
contact.
Dishwasher stop washing
but draining
Overflow occur. Check the reason of overflow
pull out the rubber cap wait for
a minute let water pour out.
Water can’t pour out from
float support when pull
out the rubber cap.
Hole in the float supply is
jammed.
Suck with dust cleaner or other
let water pour out.
Dishwasher runs but not
heat
heater element (open).
Timer contacts (open or burnt).
Wiring or terminal (burnt or
broken).
Thermostat is closed.
Replace heater element.
Replace timer.
Repair or replace.
Replace.
Dishwasher will not stop. Timer motor (inoperative).
Wiring or terminal (burnt or
broken).
Timer (open or burnt contact).
Replace timer.
Repair or replace.
Replace timer.
Dishwasher runs with
door open
Defective door safety switch. Replace door safety switch.
Motor hums but will not
start or run.
Start winding(open).
Motor (bad bearings or locked
rotor).
Replace motor.
Replace motor.
Motor trips out on in
terminal thermal overload
protector.
Start relay not dropping out.
Improper voltage.
Seal faces binding.
Motor shaft binding.
Motor windings shorted.
Glass or foreign items in pump.
Replace start relay.
Check voltage.
Repair or replace.
Repair or replace.
Repair motor.
Clean and clear area.