CONTROLS
Operating Instructions
6
Press to turn the dehumidifier on and off.
) Display
Shows the set % humidity level from 35% to 85% or auto start/stop time
(0~24) during setting, then shows the actual 5% accuracy) room %
humidity level in a range of 30% RH(Relative Humidity) to 90%RH
(Relative Humidity).
Error Codes and Protection Codes:
AS - Humidity sensor error--Unplug the unit and plug it back in. If error
repeats, call for service.
ES - Temperature sensor error-- Unplug the unit and plug it back in. If
error repeats, call for service.
P1 - Unit is defrosting-- Allow the unit time to automatically defrost. The
error will clear after the unit self defrosts.
P2 - Bucket is full or the bucket is not in right position--Empty the bucket
and replace in the right position.
E1 - unit malfunction -- Unplug the unit and plug it back in. If error repeats,
call for service.
INDICATOR
LIGHT FUNCTION
Power Light (Green):
When the unit is first connected to an electrical outlet, the (green) power
light will be flashing until the “on/off” button is pressed. When the “on/off” but-
ton is activated, the power light turns to a state “on” condition. The dehu-
midifier will automatically default to the factory default setting:
Humidity Setting: 60%
Fan Speed: High
IMPORTANT NOTE: Depending on the humidity conditions of the sur-
rounding environment, the dehumidifier may not start automatically when
the “on/off” button is pressed (see dehumidifier operating instructions for
details). In the event of a power failure, the unit will default to the last pro-
gram setting that was used when power is restored.
Water Full Indicator Light (Red):
When the water tank is full and/or incorrectly positioned inside the cabinet,
the (water full) red light turns on and remains on until such time the tank is
emptied and/or correctly re-positioned. This condition will result in the
immediate shut down of the dehumidifying system (both compressor and
fan motor operation are terminated). This is a safety feature. When the
water tank is emptied and/or correctly re-positioned, the dehumidifier will
resume operation automatically. NOTE: It may take several minutes before
operating conditions resume.
Memory Setting:
Each time the unit is disconnected/re-connected and/or in the event of a
power failure, the electronic circuit board automaticallydefaults to the last
program setting that was used. It may take several minutes before operat-
ing conditions resume.
NOTE: In the event of a power failure, all previous settings are automati-
cally erased/cancelled. If your program setting was different than above
(default setting) it will be necessary to re-program your settings. When the
unit is switched “off” manually (using the on/off keypad) the unit will always
default to the last program setting that was used.