Danby DPA120B3WDB User Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
Remove the
upper drain
plug
Continuous
drain hose
Installation Instructions
WATER DRAINAGE
During dehumidifying modes, remove the upper drain plug from the
back of the unit, install the drain connector (5/8” universal female con-
necter) with 3/4” hose (not included). For the models without a drain con-
nector, just attach the drain hose to the hole. Place the open end of the
hose directly over the drain area in your basement floor. Please refer to
Fig.22.
During heating pump mode, remove the lower drain plug from the back of
the unit, install the drain connector(5/8 universal female connector) with
3/4 hose (not included). For the models without drain connector, just
attach the drain hose to the hole. Place the open end of the hose directly
over the drain area in your basement floor. Please refer to Fig.23.
When the water level of the bottom tray reaches a predetermined level,
the unit beeps 8 times, the digital display area shows P1. At this time
the air conditioning/dehumidification process will immediately stop.
However, the fan motor will continue to operate (this is normal).
Carefully move the unit to a drain location, remove the bottom drain plug
and let the water drain away (Fig.24). Restart the machine until the P1
symbol disappears. If the error repeats, call for service.
NOTE: When operating or draining water always protect carpeting or
floors from possible water spillage.
NOTE: Be sure to reinstall the bottom drain plug before using the unit.
Fig.22
Fig.23
Fig.24
14
Continuous
drain hose
Remove the
lower drain
plug
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 35 36

Comments to this Manuals

No comments