Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
FOR YOUR SAFETY: Read these instructions carefully before operating the unit.
ELECTRICAL SPECIFICATIONS
1. All wiring must comply with local and national electrical codes and must be installed by a quali ed electrician. If you
have any questions regarding the following instructions, contact a quali ed electrician.
2. Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.
3. This 115V or 230/208V air conditioner uses 11.7 or less nameplate amps and may be used in any properly wired,
general purpose household receptacle. See Table 1 for speci cations for individual branch circuit.
4. For your safety and protection, this unit is grounded through the powercord plug when plugged into a matching wall
outlet. If you are not sure whether your wall outlet is properly grounded, please consult a quali ed electrician.
5. The wall outlet must match the 3-prong plug on the service cord supplied with the unit. DO NOT use plug adapters.
See Table 2 for receptacle and fuse information.
6. The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of
the unit, above the powercord.
TABLE 1
Suggested Individual Branch Circuit
Nameplate Amps *AWG Wire Size
11.7 or less 14
AWG- American Wire Guage
*Based on copper wire at 105°C (221°F) temperature
rating.
TABLE 2
Recept and Fuse Types
Model DAC150EC/UB1GDB DAC180EC/UB1GDB DAC250EC/UB1GDB
Rated Volts 125 240 250
Amps 15 15 30
Wall Outlet
Fuse Size 15 15 20
Time Delay Fuse Plug Type
(or Circuit Breaker)
Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.
2