Danby DWC1534BLS User Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
8
Installation Instructions - Intergrated Application
Preparing the
Enclosure
Tools You Will
Need
Carpenter’s
Square
Measuring
Tape
Level
Drill & Hole Saw set
Gloves
Safety Glasses
Flashlight
It is recommended that you do
not install the wine cooler into a
corner (i.e. directly beside a
wall). This is to allow the door to
have a greater than 90° opening
swing. A limited door swing will
prevent the shelves from sliding
out as intended, and may lead to
damaging the door gasket.
The rough cabinet opening
must be on a level floor area
and at least 23
7
/8
” (60.64cm)
deep* by 15” (38.1cm) wide.
The opening should also have a
height of at least 34
1
/16
(86.52cm).
The electrical outlet may be
positioned from within either
side of the adjacent cabinetry, or
the rear of the shaded area (as
shown in Fig. D).
Important: If the electrical out-
let is surface mounted (not flush)
within the enclosure, the
depth
requirement for the installation
may be affected.
If the electrical outlet is located
inside the adjacent cabinetry, cut
a 1
1
/2
(3.81cm) diameter hole to
admit the power cord.
WARNING!
While performing the
installations described in
this section; gloves, safety
glasses or goggles should
be worn.
Electrical Requirements
The appliance must be con-
nected to an individual and
properly grounded electrical
outlet, protected by a 15 or
20 ampere circuit breaker
or time delay fuse.
*The listed depth requirement for the installation is assuming that the electrical outlet is located in the
adjacent cabinetry or is flush mounted in the rear wall, not surface mounted in the enclosure.
IMPORTANT!
Door Swing
Do not include the door
within the enclosure; leave
it outside of the enclosure
to prevent the door swing
from being obstructed.
}
}
}
}
Fig D
1
3
4
2
6
Electrical
Access*
Fig D
1 23
7
/8
” min. depth
2 34
1
/16
” from under-
side of countertop
to floor.
3 15” min. width
4 2” of depth given
for Elec. Access*
5 1 1/2” dia. hole (if
outlet is in
adjacent cabinetry).
6 Cabinets square
and plumb
5
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 31 32

Comments to this Manuals

No comments