Danby DKC445BL Service Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 15
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
1ChromeRail(forattachmentto Worktop)
4Self-TappingScrews(toattachchromerail)
1CO2CylinderSupportStand
1CO2Cylinder(empty)
1CO2Regulator(high/lowpressuregauges)
1CO2AirLineHose(red)
2CO2AirLineHoseConnectors(black)
1BeerKegCoupler
1BeerTowerUnit(completewithfaucet,hoseandwingnut)
1 RubberWasher(tobeinstalledinsidewingnut)
1BeerTower(QuickConnect)BayonetAttachment(beertowerinstallation)
4 MachineScrews(toattachbayonettobeertower)
1Gasket(beertowerbase)
1 PullHandle(beertowerfaucet)
1 BeerKegStand(requiredfor30literkeginstallationsonly)
1 ProtectivePlate(refrigeratorcabinetfloor)
2CantileverWireShelves(conversiontoallrefrigeratorapplication)
1Chill'nTapExteriorCabinetPlug(locatedonworktop)
1CO2AirLineHosePlug(locatedexteriorrearcabinet)
1PlasticDripTray(2piece)
WARNING:CO2Cylinderswhenchargedcontainhigh-pressurecompressedgaswhichcanbe
hazardousif nothandledproperly,ReadandunderstandthefollowingproceduresforC02cylinders
beforeinstallation,
1. AlwaysconnectCO2gascylindertoa regulator.Failuretodosocouldresultinanexplosion
with possible death or injury when the cylinder valve is opened.
2. Never connect C02 gas cylinder directly to beer keg.
3. Always secure C02 gas cylinder in an "upright" position.
4. Always keep CO2 gas cylinder away from heat.
5. Never drop or throw CO2 gas cylinder.
6. Always check the D.O.T. (Department of Transport) test date located on the neck of the cylinder
before installation. If over five (5) years, do not use, return the gas cylinder to gas supplier.
7. Never connect a product container unless there are two (2) safety mechanism's in the pressure
system;
(a) One at or on the CO2 regulator. (the regulator supplied with this unit is inclusive of such a
safety mechanism)
(b) One at or on the product container coupler or in the pressure gas line. (the keg coupler
supplied with this unit is inclusive of such a safety mechanism)
8. Always ventilate area after any leakage of CO2.
If it becomes difficult to breathe and/or your head starts to ache, abnormal concentrations of
carbon dioxide (CO2) may be present in the area, CLOSE THE MAIN VALVE ON THE CO2 CYLINDER,
VENTILATE AND LEAVE THE ROOM IMMEDIATELY.
C02 gas cylinders should be stored in the coolest part of the establishment (preferably) at 70°F (21°C)
and must always be securely fastened in an "upright" position.
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 14 15

Comments to this Manuals