TROUBLESHOOTING (Cont'd)
Problem Possible Causes What To Do
Sputtering draw Dispense system See "Cleaning and Maintenance" on pg. 17-18
requires cleaning.
Keg Coupler installed Check seal between keg & faucet
incorrectly
Line or dispenser Verify that there are no 'kinks' or obstructions in either
obstructions, the air line (red) or dispenser line (clear) and that
neither are frozen.
Improper draw technique see "Using Proper Draw Technique" on pg. 16.
Faucet Dripping Handle not fully returned After every pour, ensure the handle is returned to the
to close position, the off position.
Faucet requires cleaning. See "Cleaning and Maintenance" on pg. 17-18
Rapid CO2 cylinder Improper connection, air Ensure proper connection of air line at CO2 regulator,
discharge line leak. and/or check air line for possible leaks
Difficulty Faucet requires cleaning See "Cleaning and Maintenance" on pg. 17-18
Manipulating Faucet
handle
Damaged handle stem Remove handle, and connector nuts and inspect stem
for possible damage.
Abnormal beer
Dispense system See "Cleaning and Maintenance" on pg. 17-18
taste and/or smell requires cleaning.
Contaminated dispense Check hoses for possible air leaks. Ensure all
system, connections are secure and all seals are in place and
in good condition.
The beer has exceeded Replace Beer Keg.
it's shelf-life.