Danby DPAC10099 Operations Instructions Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
Air Conditioning Mode ONLY
Your window kit has been designed to fit most standard “vertical”/”horizontal” windows up to a
maximum height of 80” (203cm). For vertical window applications, multi lock positions are
provided on the edge of each slider section to secure each sliding section together.
1) Select a suitable location, making sure you have access to an electrical outlet.
2) Install the flexible hose to the rear side of the unit. Insert the hose collar on top of the
exhaust opening and twist to lock into position.
3) Install the adjustable Window Slider Kit as required (see Fig. 4a & 4b).
4) Install the opposite end of the flexible exhaust hose into the window exhaust adapter.
5) Install the window exhaust adapter into the opening in the slider section, making sure the
window slider sections are secure.
6) Plug the unit into a 115V/60Hz grounded electrical outlet.
Window Slider Kit:
Min.: 28
1
/3(67.5cm)
Max.: 80” (203cm)
Window Slider Kit:
Min.: 28
1
/
3(72cm)
Max.: 80” (203cm)
Horizontal Window
Vertical
Window
INSTALLATION
WINDOW KIT
INSTALLATION
Fig. 1
INSTALLATION ACCESSORIES
Flexible Exhaust Hose
Exhaust Nozzle
Connector
Fixture
Adjustable Window Slider Kit:
28 1/3” (72cm)- 80” (203cm)
ELECTRIC SHOCK HAZARD: To avoid the possibility
of personal injury, disconnect power to the unit before
installing or servicing.
Caution: To avoid installation/operation difficulties, read
these instructions thoroughly.
Flexible Exhaust Hose (13cm) & Exhaust nozzle con-
nector (2 pcs)... from 17
7
/10 (45cm) to 53
1
/6” (135cm)
Flexible Exhaust Hose (11cm) & Exhaust nozzle
connector (2pcs)...from 15
3
/4” (40cm) to 51
1
/5” (130cm)
Adjustable window door slider kit (3 pcs)... from 28
1
/3”(72cm) to 80” (203cm)
Fixture..... (2 pcs) & Screws..... (8 pcs)
NOTE: The exhaust/window kit must be installed at all
times when the unit is operating under AIR
CONDITIONING mode. There should be at least 11.8”
(30cm) clearance between the unit and any other objects
or building structures, and should be installed on a level
surface.
INSTALLATION
Screws
Water hose (79”/ 200cm)
Back of window panel
Tube Adapters
Fig. 2
Instructions for Assembling the Window Adapter
Kit- Fig. 2
1) Insert tube adapters through the back of the window panel.
2) Secure each tube adapter with four screws through the front
of the window panel.
3) Insert window panel extensions into window panel. Lightly
tighten the screws in the window panel to hold the extensions
in place.
Fig 3a
Fig 3b
5