Danby DCD5505W User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 23
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
3s 20s 216s 3s
1s 5s
Dir 2
Stop
Dir
1
On
Off
On
Off
Motor
Heating
element 1
Pump
THE ANTICREASE PHASE
At the end of the 10’ of cool-down, the Anti-crease led and the End led are
switched ON, the buzzer is switched ON (5 bleeps of 1”separated by 1”OFF
intervals), the program starts its anti-crease phase. It can be interrupted by the
user anytime. Its timeout is 1 hour.
At the end of the hour of anti-crease, the program definitively stops. The Anti-
crease led is off. The End led stay on.
Motor rhythm : 300” OFF / 5”ON - Direction 2 / 300” OFF / 5”ON - Direction
1
Heater and Pump: OFF
Moto
r
H
element 1
Pump
eating
Motor
Heating
element 1
Pump
300s 5s 300s 5s
Dir 2
Stop
Dir 1
On
Off
On
Off
Page view 6