Danby DCD5505W User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 23
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
The End led is lighted from the beginning of the anti-crease phase and is
extinguished when the mains supply is cut off.
Tank led does not exist on air-vented drier.
End
Tank
ID2
ID1
Normal
Store
Extra
Anticrease
4. PROGRAM SELECTION AND START
1. After the switching on of the mains supply, the user must move the EID on
one of the 15 drying programs except the position 0.
2. When the code is stable for more than 0.6”, the user can push the START
button to validate his choice.
3. The buzzer is activated during 2”.
4. There aren’t the power parts activating during 4”from Start button pushing (2”
after the end of buzzer). During this waiting time, if the chosen program is 1 to
9, the corresponding led blinks.
5. At the end of the waiting time, the selected program is started, the heater is
activated, the drum turns.
4”
Drying program start
Buzzer ON 2
Program selection Push the START button
0.6" min.
When the machine is running, the only way to modify the program is to move the
EID on the 0 position during more than 0.6”, then to place it on the new selected
program and go back to step 2 of the description below.