Danby DR240WGLP Owner's Manual Page 29

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 28
3. ELECTRICAL CONNECTIONS
Electrical Requirements
120 volt, 60 hertz, properly grounded dedicated circuit protected by a 15 amp or 20 amp circuit breaker or time delay fuse.
NOTE: Use of automatic, wireless, or wired external switches that shut off power to the appliance are not recommended for this product.
Grounding:
The power cord of this appliance is equipped with a three prong (grounding) plug which mates with a standard three-prong grounding wall receptacle to
minimize the possibility of electric shock hazard from this appliance.
The customer should have the wall receptacle and circuit checked by a quali ed electrician to make sure the receptacle is properly grounded.
Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.
Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD. DO NOT USE AN
ADAPTER. DO NOT USE AN EXTENSION CORD.
A word about GFCIs - GFCIs are not required or recommended for gas range receptacles.
Ground Fault Circuit Interrupters (GFCIs) are devices that sense leakage of current in a circuit and automatically switch off power when a threshold
leakage level is detected. These devices must be manually reset by the consumer. The National Electrical Code requires the use of GFCIs in kitchen
receptacles installed to serve countertop surfaces. Performance of the range will not be affected if operated on a GFCI-protected circuit but occasional
nuisance tripping of the GFCI breaker is possible.
INSTALLATION INSTRUCTIONS
)/(;,%/(&211(&725 5,*,'3,3(+22.83(;$03/(
+22.83([DPSOH
,QVWDOOHU,QIRUPWKH
FRQVXPHURIWKHORFDWLRQRI
WKHJDVVKXWRIIYDOYH
,QVWDOOHU,QIRUPWKHFRQVXPHURIWKH
ORFDWLRQRIWKHJDVVKXWRIIYDOYH
3UHVVXUH
UHJXODWRU
RU*DVSLSH
*DVVKXWRII
YDOYH
8QLRQ
%ODFNLURQ
SLSH
(OERZ
3UHVVXUH
UHJXODWRU
)OH[FRQQHFWRU

øIWPD[
RU*DVSLSH
$GDSWHU
*DVVKXWRII
YDOYH
(OERZ
%ODFNLURQ
SLSH
øµ
*DV)ORZLQWR5DQJH
$GDSWHU
*DV)ORZLQWR5DQJH
1LSSOHPD\
QRWEH
QHHGHG
1LSSOH
Installer: Inform the consumer of the
location of the gas shut-off valve
Installer: Inform the consumer of the location of the
gas and shut-off valve
Pressure
regulator
Adapter
Flex connector
(4 1/2 ft. max)
Adapter
Gas shut off
valve
1/2” or 3/4” gas pipe
Pressure
regulator
1/2” or 3/4” gas pipe
Gas shut off
valve
Nipple
(may not
be needed)
90° elbow
Black iron
pipe
Union
Nipple
90° elbow
Black iron
pipe 4 1/2
WARNING
(QVXUHSURSHUJURXQG
H[LVWVEHIRUHXVH
Ensure proper ground
exists before use
27
Shock Hazard: This appliance must be properly grounded. Failure to do so can result in
electric shock.
www.goedekers.com
Page view 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 67 68

Comments to this Manuals

No comments