Air Conditioning Mode ONLY
Your window kit has been designed to fit most
standard “vertical”/”horizontal” windows up to a
maximum height of 80” (203cm). For vertical
window applications, multi lock positions are
provided on the edge of each slider section to secure
each sliding section together.
1) Select a suitable location, making sure you have
access to an electrical outlet.
2) Install the flexible hose to the rear side of the unit.
Insert the hose collar on top of the exhaust opening
and twist to lock into position.
3) Install the adjustable Window Slider Kit as
required (see Fig. 3a & 3b).
4) Install the opposite end of the flexible exhaust
hose into the window exhaust adapter.
5) Install the window exhaust adapter into the
opening in the slider section, making sure the
window slider sections are secure.
6) Plug the unit into a 115V/60Hz grounded electrical
outlet.
Window Slider Kit:
Min.: 28
1
/3” (67.5cm)
Max.: 80” (203cm)
Window
Slider Kit:
Min.: 28
1
/3
(72cm)
Max.: 80”
(203cm)
Horizontal Window
Vertical
Window
There should be at least 11.8” (30cm) clearance between the unit
and any other objects or building structures, and should be installed
on a level surface. The unit does not have to be vented outside
during Dehumidifying or Fan Only mode operation.
Flexible Exhaust Hose (13cm) & Exhaust nozzle connector (2
pcs) from 17
1
/10” (45cm) up to 53
1
/6” (135cm)
Adjustable window door slider kit (3 pcs) from 28
1
/3
”(72cm) up to
80” (203cm)
Fixture..... (2 pcs)
Screws......(12 pcs)
NOTE: The exhaust/window kit must be installed at all times when
the unit is operating under AIR CONDITIONING mode.
ELECTRIC SHOCK HAZARD: To avoid the possibility of personal injury, disconnect
power to the unit before installing or servicing.
Back of Window Pane
Tube Adapters
Fig. 2
Instructions for Assembling the Window Kit- Fig. 2
1) Insert tube adapters through the back of the window panel.
2) Secure each tube adapter with four screws through the front of the
window panel.
3) Insert window panel extensions into window panel. Lightly tighten
the screws in the window panel to hold the extensions in place.
Fig. 3a
Fig. 3b
4
INSTALLATION
WARNING
WINDOW KIT
Fig. 1
INSTALLATION ACCESSORIES
Flexible Exhaust Hose
Exhaust Nozzle
Connector
Fixture
Adjustable Window Slider Kit:
28 1/3” (72cm)- 80” (203cm)
Screws
Water hose (79”/ 200cm)