Danby Diplomat DAC7037M Operations Instructions Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
Your unit is designed to evaporate condensation
under normal conditions. Howeve
r, under
extreme humidity conditions, excess condensation
may cause basepan to overflow to the outside.
The Unit should be installed where condensation
run-o
ff cannot drip on pedestrians or neighboring
properties.
Select the Best Location
A. This room air conditioner is designed to fit easily
into a single or double hung windo
w. However,
since window designs var
y, it may be necessary
to make some modifications for safe, proper
installation.
B. Make sure window and frame are structurally
sound and free from dry and rotted wood.
C. For maximum e
fficiency, install the air conditioner
on a side of a house or building which favors
more shade than sunlight. If the unit is in direct
sunlight, it is advisable to provide an awning over
the unit.
D. Provide su
fficient clearance around the cabinet
to allow for ample air circulation through the unit.
See Fig. 2. The rear of the unit should be
outdoors and not in a garage nor inside a
building. Keep unit as far away as possible from
obstacles/obstructions and at least 30" above the
floor or ground. Curtains and other objects
within a room should be prevented from blocking
the air flo
w.
E. Be certain the proper electrical outlet is within
reach of the installation. Use only a single
outlet circuit rated at 15 amps.
All wiring should
be in accordance with local and national
electrical codes.
F. DO NOT USE "REGULAR" EXTENSION CORDS
WITH
THIS UNIT. If it is necessary to use an
extension cord to connect your air conditione
r,
use an approved "air conditioner" extension cord
onl
y. (available at most local hardware stores)
G. DO NOT install unit where leakage of
combustible gas is suspected.
Your air
conditioner may fail to operate in air containing
oils (including machine oils), sulfide gas, near hot
springs, etc...
Side
obstruction
20"(508mm)
Min.
Fig. 2
Ground
Fence,
wall, or
other
obstacle.
Awning
12" Min.(305mm)
30"(762mm)
Min.
20"(508mm)
Min.
5
CAUTION
Because the compressor is located on the
controls side of the unit (left side), this side will
be heavier and more awkward to manipulate.
Inadequate support on control side of the unit
can result in personal injury and damage to your
unit and propert
y. Therefore, it is recommended
to have someone assist you during the
installation of this unit.
Installation
Page view 5
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals

No comments