1) POWER Button: On / Off
2) FAN SPEED Button: High / Low
3) TIMER Button: When unit is operating, press
TIMER to set number of hours desired until unit will
shut off.When unit is in stand-by, press TIMER to set
number of hours desired until unit will turn on.
Setting timer from 1-24 hours. To cancel the timer,
proceed as above but set the “timer off” to zero (0)
hours.
4) °C/°F Button: Press the °C/°F button to toggle
between Celsius and Fahrenheit.
5) Receiving Sensor
6) SET HUMIDITY/CURRENT HUMIDITY
DISPLAY: When machine is running, it displays the
current humidity. Press UP or DOWN buttons to
select humidity setting. The humidity is adjusted in
increments of 5% by each press. Adjustable range is
within 30% RH to 90% RH. 10 seconds after
setting humidity, the display will change back to the
current humidity.
7) CURRENT TEMP/ TIMER SET DISPLAY:
When machine is running, it displays the current
temperature. Press the TIMER button to set the
machine to shut off automatically after specified
amount of time. 10 seconds after displaying the timer,
the display will change back to current temperauture.
8) DEFROST LIGHT: When temperature is low,
unit enters defrost mode and defrost light illuminates.
9) BUCKET FULL LIGHT: When water tank is
full, bucket full light illuminates.
OPERATING INSTRUCTIONS
1
2
3
8
6
7
4
5
4
REMOTE CONTROL
9
1
3
2
4
5
1) Power Key: On / Off
2) Fan Speed Key: High/Low
3) On / Off Timer Key:
In running mode: Auto switch Off
In standby mode: Auto switch On
4) Temperature display selector button
(Celsius / Fahrenheit): Press the°C/°F
switch button to toggle between °C and °F.
5) Timer/ Temperature Buttons:
A) Used for adjusting the timer and
thermostat.
B) The default display is room
temperature.
C) When “+” or “-” button is pressed,
the set temperature is displayed and may
be adjusted. After 10 seconds the display
will revert back to room temperature.
The remote operates within a range of 6
meters (16.4 ft.)from the receiver located
inside the main unit. Any obstruction
between the receiver and remote may
cause signal interference, limiting the
ability to program the main unit.
This Class B digital apparatus complies
with Canadian ICES-003.
BATTERIES: Remove the cover on the back of the remote controller and insert the
batteries with the (+) and (-) poles pointing in the proper direction.
CAUTION: Use only AAA or IECR03 1.5V batteries. Remove the batteries if the
remote controller is not used for one month or longer. Do not attempt to recharge the
supplied batteries. All batteries should be replaced at the same time. Do not dispose
of the batteries in a fire as they may explode.
The functions work the same as your dehumidifiers touch controls.